5 ½ Display
199999 count, 4.3 inch TFT LCD display, Hold measurement function
Mathematical operations and reading statistics
Mathematical operations mainly include 5 functions: statistics, limits, dB, relative operations and dBm. Choose different mathematical operation functions to meet the measurement requirements of different conditions. The math operation function is suitable for voltage, current, resistance, capacitance, frequency/period and temperature measurement. The dB and dBm operation are only suitable for voltage measurement.
Display mode
Support users to view the measured data in four ways:
"number", "bar graph", "trend graph" and "histogram".
Dual display function
When measuring the voltage or current of an AC signal, you can also measure its frequency. At this time, the voltage or current is displayed, and the frequency value is also displayed.
Powerful help system
Help you quickly become familiar with the instrument.
Mass storage
Internal 32G NandFlash + external USB flash drive. Worry-free storage of setup and measurement data.

|
Model |
Description |
|---|---|
|
K |
thermocouple test lead |
|
UT-S04A
|
serial line |
|
K
|
thermocouple test lead |
Maintenace and Cleaning
(2) Cleaning Check the instrument and probe frequently according to the operating conditions. Fellow the steps to clean the surfaces of the instrument.
Please use a soft cloth to wipe dust on the surface of the instrument and probe. When cleaning the LCD panel, be careful not to scratch the transparent protective film.
Power off the instrument first and wipe the instrument with a soft cloth.Use a mild detergent or water to clean if necessary.
Do not use any abrasive chemical cleaners as they may damage the instrument or the probe.
Warning: Make sure the instrument is completely dry before rebooting. Moisture may cause electrical short-circuit or even personal injury!
Why is there no waveform output from the signal generator?
1) Check whether the BNC cable is properly connected to the channel output.
2) Check whether the key CH1 or CH2 is turned on.
3) Save the current settings of the instrument to a USB flash drive and "restore factory settings", then restart the instrument.
4) If the instrument still can't work normally, please contact your UNI-T dealer or local offices for support.
Why the signal generator cannot recognize U disk?
2) Make sure you are using Flash type USB flash drive device, this instrument does not support hard disk type USB flash drive device.
3) Restart the instrument and insert the USB flash drive again to see if it works properly.
4) If the USB flash drive still can not be recognized, please contact UNI-T dealer or local office and let us serve you.
No screen display(blank screen)
1) Check whether the power supply is connected properly.
2) Check whether the power switch on the rear panel is set to "I".
3) Check whether the power switch on the front panel is connected .
4) Restart the instrument.
5) If the instrument still can't work normally, please contact your UNI-T dealer or local offices for support.
Why is four-wire measurement used in resistance testing? What is the difference compared to two-wire measurement?
What are the difference between UT800 and UT8000 series?
2、The maximum data gruop for UT8000 is 20,000. while only 10,000 data gruops for UT800.
3、The maximum test speed of UT8000 is 5000/s as for UT800 is 100/s.
4、UT8000 interfaces: USB, RS232 and LAN, also with standard protocol; UT800 interfaces: USB and RS232