Alternate trigger
It can be effectively applied to trigger signals without frequency correlation.
Grade Display
Grade display can view the worst case of changing waveforms, capture rare and abnormal signals
Automatic parameter measurement
With 34 kinds of automatic parameter measurement, 5 groups of customizable parameter display
Standard square wave output
With 10hz, 100hz, 1Khz, 10Khz local signal standard square wave output
Brand new AUTO strategy
The state after AUTO can be set
XY mode (also called Lissajous graphics mode)
Can measure the phase difference between two signals of the same frequency
ZOOM function
You can observe the overall situation and details of the waveform
Math function
Support addition, subtraction, multiplication, division, and waveform calculation functions
| Specifications | UTD2052CL | UTD2025CL | UTD2102CL+ | UTD2052CL+ | UTD2152CL | UTD2072CL |
|---|---|---|---|---|---|---|
| Model | UTD2052CL | UTD2025CL | UTD2102CL+ | UTD2052CL+ | UTD2152CL | UTD2072CL |
| Bandwidth | 50 MHz | 25 MHz | 100MHz | 50MHz | 150 MHz | 70 MHz |
| Analog Channels | 2 | 2 | 2 | 2 | 2 | 2 |
| Real-Time Sample Rate | 500 MSa/s | 250 MSa/s | 500MSa/s | 500MSa/s | 500MSa/s | 500MSa/s |
| Max. Memory Depth | 25 kpts | 25 kpts | 64 kpts | 64 kpts | 64 kpts | 64 kpts |
| Waveform Capture Rate | 2,000 wfms/s | 2,000 wfms/s | 5,000 wfms/s | 5,000 wfms/s | 5,000 wfms/s | 5,000 wfms/s |
| Digital Channels | / | / | / | / | / | / |
| Waveform Generator | / | / | / | / | / | / |
| Price / Status | Obsolete | Obsolete | — | — | Obsolete | Obsolete |
| Model | Description | ||
|---|---|---|---|
| ACCESSORIES | |||
| UT-P01 | Probe factor:(10:1) Bandwidth: 25MHz.voltage:600Vpp | ||
| UT-P03 | Probe factor:(10:1) Bandwidth: 60MHz.voltage:600Vpp | ||
| UT-P04 | Probe factor:(10:1) Bandwidth: 100MHz.voltage:600Vpp | ||
| UT-P05 | Probe factor:(10:1) Bandwidth: 200MHz.voltage:600Vpp | ||
| UT-P20 | Passive probe: (100:1) Bandwidth: 250MHz. voltage: 1500V | ||
| UT-P21 | Passive high voltage probe: (1000:1) Bandwidth: 40MHz voltage: DC 10kV/AC 7kVrms | ||
| UT-V23 | High voltage probe: (100:1) Bandwidth: 100MHz, voltage: 2000Vpp | ||
| UT-P30 | Differential probe: (10:1/100:1) Bandwidth: 100MHz, differential voltage: 800Vpp | ||
| UT-P31 | High voltage differential probe: (100:1/1000:1) Bandwidth: 100MHz, differential voltage: 1500Vpp | ||
| UT-P32 | Differential probe: (1000:1/100:1) Bandwidth: 50MHz, Input differential voltage: 3000Vpp | ||
| UT-P33 | Differential probe: (1000:1/100:1) Bandwidth: 70/50MHz, differential voltage: 14KVpp | ||
| UT-P35 | High voltage Differential probe: 1:50, 130V (DC+peakAC); 1:500, 1300V (DC+peakAC), Bandwidth: 50MHz, Precision: 2% | ||
| UT-P36 | High voltage Differential probe: 1/200:560 (DC+peakAC), 1/2000:5600 (DC+peakAC), Bandwidth: 100MHz, Precision: 2% | ||
| UT-P40 | Conversion ratio: 50mV/A, 5mV/A, Current range: 0.4A~60A, Frequency: DC~100kHz, voltage: 600Vrms | ||
| UT-P41 | Conversion ratio: 100mV/A, 10mV/A, Current range: 50mA~100A, Frequency: DC~100kHz, voltage: 600Vrms | ||
| UT-P43 | Current range: 20A AC/DC, Frequency: DC~25MHz, Conversion ratio: 100mV/A | ||
| UT-P44 | Current range: 40A AC/DC, Frequency: DC~50MHz, Conversion ratio: 50mV/A | ||
| UT-P4030D | 30A/DC~100MHz High frequency current probe, Range: 30A/5A, Frequency: DC~100MHz, Rise time: ≤3.5ns | ||
| UT-P4100A | 100A/600kHz Low frequency current probe, Range: 100A/10A, Frequency: DC~600kHz, Rise time: ≤583ns | ||
| UT-P4100B | 100A/2MHz Low frequency current probe, Range: 100A/10A, Frequency: DC~2MHz, Rise time: ≤175ns | ||
| UT-P4150 | 150A/DC-12MHz High frequency current probe, Range: 150A/30A, Frequency: DC~12MHz, Rise time: ≤29ns | ||
| UT-P4500 | 500A/DC~5MHz High frequency current probe, Range: 500A/75A, Frequency: DC~5MHz, Rise time: ≤70ns | ||
| UT-D14 | USB 2.0 double-head printing cable:1.5m | ||
| UT-D15 | USB 2.0 double head communication cable:1.5M | ||
Download Brochure