2 in 1
Oscilloscope & Multimeter
More parameter measurement types
Display cursor peak-to-peak value, amplitude, maximum value, minimum value, top value, bottom value, middle value, average value, rms value, overshoot, preshoot, frequency, period, rise time, fall time during automatic measurement , positive pulse width, negative pulse width, positive duty cycle, negative duty cycle, rise delay, fall delay measurement of a total of 27 kinds
Monochrome display
Single color display can be set, more suitable for outdoor use under strong light
Fully automatic setup function
Automatic setting function (AUTO SCALE) Vertical and time base gears can be automatically adjusted with signal changes without manual intervention
Auto configuration
Powerful automatic setting function, fast and accurate automatic setting for signals containing any DC component
| Specifications | UTD1202C | UTD1102C | UTD1062C |
|---|---|---|---|
| Model | UTD1202C | UTD1102C | UTD1062C |
| Bandwidth | 200 MHz | 100 MHz | 60 MHz |
| Analog Channels | 2 | 2 | 2 |
| Real-Time Sample Rate | 1 Gsa/s | 500 Msa/s | 250 Msa/s |
| Max. Memory Depth | 7.5 kpts | 7.5 kpts | 7.5 kpts |
| Waveform Capture Rate | - | - | - |
| Digital Channels | - | - | - |
| Price / Status | Obsolete | — | Obsolete |
| Model | Description | ||
|---|---|---|---|
| ACCESSORIES | |||
| UT-H03 | Probe factor:(10:1) Bandwidth: 60MHz.voltage:600Vpp | ||
| UT-H04 | Probe factor:(10:1) Bandwidth: 100MHz.voltage:600Vpp | ||
| UT-H05 | Probe factor:(10:1) Bandwidth: 200MHz.voltage:600Vpp | ||
| UT-P20 | Passive probe: (100:1) Bandwidth: 250MHz. voltage: 1500V | ||
| UT-P21 | Passive high voltage probe: (1000:1) Bandwidth: 40MHz voltage: DC 10kV/AC 7kVrms | ||
| UT-V23 | High voltage probe: (100:1) Bandwidth: 100MHz, voltage: 2000Vpp | ||
| UT-P30 | Differential probe: (10:1/100:1) Bandwidth: 100MHz, differential voltage: 800Vpp | ||
| UT-P31 | High voltage differential probe: (100:1/1000:1) Bandwidth: 100MHz, differential voltage: 1500Vpp | ||
| UT-P32 | Differential probe: (1000:1/100:1) Bandwidth: 50MHz, Input differential voltage: 3000Vpp | ||
| UT-P33 | Differential probe: (1000:1/100:1) Bandwidth: 70/50MHz, differential voltage: 14KVpp | ||
| UT-P35 | High voltage Differential probe: 1:50, 130V (DC+peakAC); 1:500, 1300V (DC+peakAC), Bandwidth: 50MHz, Precision: 2% | ||
| UT-P36 | High voltage Differential probe: 1/200:560 (DC+peakAC), 1/2000:5600 (DC+peakAC), Bandwidth: 100MHz, Precision: 2% | ||
| UT-P40 | Conversion ratio: 50mV/A, 5mV/A, Current range: 0.4A~60A, Frequency: DC~100kHz, voltage: 600Vrms | ||
| UT-P41 | Conversion ratio: 100mV/A, 10mV/A, Current range: 50mA~100A, Frequency: DC~100kHz, voltage: 600Vrms | ||
| UT-P43 | Current range: 20A AC/DC, Frequency: DC~25MHz, Conversion ratio: 100mV/A | ||
| UT-P44 | Current range: 40A AC/DC, Frequency: DC~50MHz, Conversion ratio: 50mV/A | ||
| UT-P4030D | 30A/DC~100MHz High frequency current probe, Range: 30A/5A, Frequency: DC~100MHz, Rise time: ≤3.5ns | ||
| UT-P4100A | 100A/600kHz Low frequency current probe, Range: 100A/10A, Frequency: DC~600kHz, Rise time: ≤583ns | ||
| UT-P4100B | 100A/2MHz Low frequency current probe, Range: 100A/10A, Frequency: DC~2MHz, Rise time: ≤175ns | ||
| UT-P4150 | 150A/DC-12MHz High frequency current probe, Range: 150A/30A, Frequency: DC~12MHz, Rise time: ≤29ns | ||
| UT-P4500 | 500A/DC~5MHz High frequency current probe, Range: 500A/75A, Frequency: DC~5MHz, Rise time: ≤70ns | ||
Download Brochure