High‑Density Synchronous Acquisition System
- Ultra Scalable Architecture:
Supports up to 64 units synchronized, delivering 512 channels (64 × 8 CH) for large scale, high channel count applications. - High Speed Optical Interface (Optional):
Optional 10 Gbps optical fiber interface ensures reliable, high bandwidth data transmission over long distances. - Flexible Variable Sampling Rate Transmission:
Supports variable sampling rate data streaming, enabling efficient acquisition tailored to different test scenarios. - Complete Software Support:
Comes with calibration and data acquisition software, simplifying system setup, synchronization, and measurement workflow.
Industrial Grade Near end / Far end Control Platform
- Supports flexible near end and far end deployment, enabling reliable integration with external displays and industrial control equipment
- Provides web based remote access for monitoring and control via PCs and mobile devices
- Enables host PC (upper computer) control, supporting centralized system management and automated test workflows
- Designed for industrial and multi instrument environments, improving operational efficiency and system scalability
All in One Integrated Signal Measurement Platform
- Oscilloscope
High performance oscilloscope with bandwidth options up to 1 GHz, enabling precise time domain signal observation. - Protocol Analyzer
Supports 12+ protocol analysis, simplifying debugging and validation of digital communication interfaces. - Signal Generator
Integrated 50 MHz signal generator for stimulus generation and functional testing within the same platform. - Spectrum Analyzer
Built in spectrum analysis with 4 million point enhanced FFT for detailed frequency domain insight. - Digital Voltmeter
Integrated 4 digit digital voltmeter enables accurate voltage measurements without external instruments. - Frequency Counter
High resolution 7 digit frequency counter provides precise frequency and timing measurements. - Bode Plot Analyzer
Frequency response analysis supports gain and phase characterization of control and power systems. - Power Analysis
Integrated power analysis with 12+ test items enables efficient power integrity and performance evaluation.
Three Phase Power Analysis Solution
- High Precision Synchronous Measurement
Accurate, synchronized acquisition of three phase voltage and current for reliable power analysis. - One Click Comprehensive Analysis
Fast access to key metrics including power quality, harmonics, ripple, efficiency, and DQ0 analysis. - Intuitive Real Time Visualization
Real time space vector display accelerates motor drive debugging and performance optimization. - Designed for Modern Power Applications
Ideal for EV drive systems, industrial motors, and renewable energy inverters. - Efficient R&D and Fault Diagnosis Tool
Delivers fast, repeatable results for R&D validation, system evaluation, and troubleshooting.
Power Analyzer
- Designed for Modern Low Voltage, High Current Power Systems
Ideal for advanced chip level and high density power architectures, ensuring stable and clean power delivery. - Comprehensive Power Integrity Analysis (12 Key Tests)
Covers up to 12 essential power integrity test items, including voltage quality, noise, ripple, dynamic response, and power efficiency evaluation. - Input Analysis: Power Quality, Harmonic Analysis, Inrush Current
- Switching Analysis: Switching Loss, Safe Operating Area (SOA), Slew Rate, Rds (on), Modulation Analysis
- Output Analysis: Ripple Analysis, Power Efficiency, Transient Response, ON/OFF time

OPTIONS
|
Model |
Description |
|---|---|
|
UPO6000LP-BND
|
All Serial Bus Trigger and Decode Options (including EMBD, AUTO, Audio, MIL-STD, ARINC, Manchester) |
|
UPO6000LP-AUTO
|
Automotive Serial Bus Trigger and Decode Option (including CAN, CAN-FD, LIN, FlexRay, SENT) |
|
UPO6000LP-SENT
|
Automotive Sensor Bus Trigger and Analysis Option (SENT) |
|
UPO6000LP-FLEX
|
Automotive Serial Bus Trigger and Analysis Option (FlexRay) |
|
UPO6000LP-LIN
|
Automotive Serial Bus Trigger and Analysis Option (LIN) |
|
UPO6000LP-CAN
|
Automotive Serial Bus Trigger and Analysis Option CAN |
|
UPO6000LP-CANFD
|
Automotive Serial Bus Trigger and Analysis Option CAN-FD |
|
UPO6000LP-AUDIO
|
Audio Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM) |
| UPO6000LP-ARINC429 |
Aerospace Serial Bus Trigger and Analysis Option (ARINC429) |
ACCESSORIES
|
Model |
Description |
|---|---|
|
UT-PD1500
|
1.5GHz bandwidth, 10:1 attenuation ratio, ±4V dynamic range active differential probe |
|
UT-PD2500
|
2.5GHz bandwidth, 10:1 attenuation ratio, ±4V dynamic range active differential probe |
|
UT-PA1000
|
1GHz bandwidth, 10:1 attenuation ratio, ±4V dynamic range Single-ended active probe |
|
UT-PA2000
|
2GHz bandwidth, 10:1 attenuation ratio, ±4V dynamic range Single-ended active probe |
|
UT-P07A
|
Probe factor:(10:1) Bandwidth: 500MHz.voltage:600Vpp |
|
UT-P08A
|
Probe factor:(10:1) Bandwidth: 350MHz.voltage:600Vpp |
|
UT-P20
|
Passive probe: (100:1) Bandwidth: 250MHz. voltage: 1500V |
|
UT-P21
|
Passive high voltage probe: (1000:1) Bandwidth: 40MHz voltage: DC 10kV/AC 7kVrms |
|
UT-V23
|
High voltage probe:(100:1)Bandwidth: 100MHz voltage: 2000Vpp |
|
UT-ISOT
|
Isolation transfomer for Bode plot application (Hardware) |
|
UT-M13X
|
Oscilloscope Signal Protocol Demonstration Board |
What is the maximum allowable input voltage for the Signal Generator (Gen) output port on the UPO6000LP Series high-resolution oscilloscope?
What kind of oscilloscope is the UPO6000LP Series?
What are the valid signal requirements for Auto Setup on the UPO6000LP Series?
- Signal frequency is not less than 10 Hz
- Signal amplitude is not less than 12 mVpp
- Duty cycle of a square wave signal is greater than 5%
Whatmodels are included in the UPO6000LP Series? What are the key differences between different models?
▶ 4-channel models
- UPO6104LP (1 GHz)
- UPO6054LP (500 MHz)
- UPO6034LP (350 MHz)
- UPO6108LP (1 GHz)
- UPO6058LP (500 MHz)
- UPO6038LP (350 MHz)
- The 4-channel models support a built-in signal generator (Gen), making them suitable for integrated excitation and measurement applications.
- The 8-channel models support three-phase power analysis, making them suitable for high-density multi-channel acquisition and power system testing.
What protocol decoding and analysis capabilities are supported by the UPO6000LP Series?
Need Help?
We are here!
Download Brochure