The Four-Quadrant Bipolar Power Supply ANBPS Series employs advanced technology combining switching power supply and linear power amplifier technologies. It integrates the functions of both DC source load and high-frequency AC power supply, featuring three output modes: DC, DC+AC, and AC. It is capable of measuring voltage, current, and other parameters, while supporting sequence, synchronous trigger, parallel operation, and external analog input functions. It ensures a reliable and stable power supply operation through multiple protection functions such as overvoltage, overcurrent, and overtemperature. Its superior programming feature, combined with high bandwidth and fast response characteristics, provides efficient and precise power supply variation test solutions for vehicle-mounted and airborne electrical equipment.
Relevant automotive electrical and electronic performance standards
ISO16750-2: Road Vehicles—Environmental Conditions and Testing for Electrical and Electronic Equipment—Part 2: Electrical Loads
GB/T28046-2: Road Vehicles—Environmental Conditions and Testing for Electrical and Electronic Equipment—Part 2: Electrical Loads
FMC1278: Electromagnetic Compatibility Specification for Low and High Voltage Electrical/Electronic Components and Subsystems
VW80000: Electrical and Electronic Components in Motor Vehicles up to 3.5t—Test Objectives, Conditions, and Requirements
LV124: Electrical and Electronic Components in Motor Vehicles up to 3.5t—Test Objectives, Conditions, and Requirements
- High power per unit: A single unit (3U full width) can output a maximum power of 800W.
- Short rise time: No-load or full-load rise time is 3.5µs.
- Low output noise: Output noise is less than 8mVrms.
- Wide bandwidth: Under full-load rated resistive conditions, it can output the rated voltage from 0 to 100kHz (-3dB).
- Powerful waveform generation: Includes sine wave, triangular wave, square wave, along with 16 user-defined waveforms and 16 built-in waveforms. Combined with program and script programming modes, it can generate any test waveforms.
- The load is set with CF and PF values to simulate various types of loads.
- Four-quadrant operation: Positive voltage positive current (first quadrant), negative voltage positive current (second quadrant), negative voltage and negative current (third quadrant), positive voltage and negative current (fourth quadrant).
- Diverse output modes: Three output modes, including AC output, DC output, and AC+DC output, each capable of operating in CC and CV modes.
- Adjustable response time function: The voltage response speeds are 3.5µs, 10µs, 35µs, and 130µs, respectively; the current response speeds are 130µs, 190µs, 700µs, and 2ms, respectively.
- Comprehensive measurement functions: It is equipped with robust measurement functions, providing DC, AC, and DC+AC measurements.
- Powerful waveform editing function: It is equipped with a waveform editing function, allowing selection from sine wave, triangular wave, square wave, 16 built-in waveforms, and 16 user-defined waveforms.
- Soft start/stop control: When enabling/disabling the power output, the time for the output value to rise from zero/setting value or from the setting value/zero is adjustable, with a setting range of 0.1ms to 1000s.
- High precision output control: It allows fine adjustment of DC voltage/current, with a voltage input range of -2.0000 to 2.0000V and a current input range of -0.5000 to 0.5000A.
- S-terminal measurement compensation function: It enables remote voltage sampling for line compensation.
- Power amplifier function: It provides power amplification of external input signals according to the set gain.
- Parallel operation function: It enables parallel output, supporting up to 10 units in parallel, with the function and performance after paralleling remaining consistent with a single unit.
- Communication function: Communication with the host computer via a communication interface facilitates operation.
- Memory function: It features multiple memory groups for storing setup parameters, meeting the demands of rapid production line testing.
- Comprehensive host computer functions: A user-friendly and convenient operation interface enables all functions to be realized through the host computer.
Operation Mode
Four-quadrant operation characteristics

Abundant Waveform Types
Rich built-in waveforms and user-defined waves enable the generation of any test waveforms.

Powerful and Flexible Waveform Programming Function
Built-in waves and user-defined waves can be freely combined as waveform units to create waveform programs; multiple waveform programs can then be arranged into a waveform script.

Flexible Parallel Operation
It supports up to 10 units in parallel, expanding power up to 8kW. The functionality and performance of the entire parallel system remain consistent with a single unit.

High Dynamic Response Characteristic
The fastest rise time is less than 3.5µs with negligible overshoot.

Output Noise
Low noise, with output noise less than 8mVrms.

High Bandwidth Function
It can output the rated voltage from 0 to 100kHz, and half the rated voltage (-3dB) above 100kHz.

Automotive Low-voltage System Electrical Performance Testing