The N17DP(F) Series Parallel Cabinet is designed for centralized power supply systems in ground power units. When multiple ground power units are paralleled, the parallel cabinet aggregates the power outputs and, in conjunction with voltage drop compensators, distributes 400Hz power to multiple aircraft positions. It is primarily applied in centralized power supply scenarios such as maintenance hangars and aprons.
- Support centralized power supply systems with a maximum capacity of 540kVA.
- Built-in paralleling inductor effectively reduces circulating currents during the paralleling process and internal losses.
- Protection grade of lP55, meeting outdoor installation requirements.
- Paralleling cabinet and voltage drop compensator share uniform external dimensions, ensuring standardized equipment manufacturing and consistent aesthetic installation layout.
- Flexible expansion of output channels coupled with a voltage drop compensator, allowing distribution of any desired number of outputs.
| Model | AN17DP-300(F) | |
| Quantity of power units | 1 – 3 | |
| Input/output parameter | Rated power | 3×180KVA |
| Distribution system | Three-phase four-wire | |
| Rated voltage | 3×115/200V | |
| Rated current | 3×1560A | |
| Frequency | 400Hz±10Hz | |
| Output expansion | Any path expansion | |
| Efficiency | ≥99% | |
| Environment | Protection grade | IP55 |
| Ambient conditions | -40℃-+60℃ | |
| Relative humidity | 10~100%(no condensation) | |
| Reliability | MTBF | 100,000 hours |
| MTTR | ≤20min | |
| Volume W*H*D(mm) | 600*1700*1030 | |
| Weight (kg) | 150 | |
Applied to areas where aircraft are concentrated, such as near-gate positions, remote-gate positions, maintenance hangars, and airport aprons.